Nova statstrip glucose linearity kit
WebStat EMS measures lactate, hemoglobin, hematocrit, glucose and ketone from a capillary blood drop. Results are available in seconds. By combining single-use biosensor … WebStatStrip Glucose Level 1 Control Solution StonyBrook 1/Bt 1410741 Nova Biomedical — 41741 Please note this item may ship standard ground delivery service. If you need …
Nova statstrip glucose linearity kit
Did you know?
WebNova StatStrip Glucose Meter Training Fast Facts Revised 4/2024 . Nova StatStrip Glucose Meter • Reagent Requirements Nova StatStrip Glucose Test Strips Nova StatStrip Glucose Control Solution Storage Temperature Room Temperature (<40 °C) Room Temperature (<40 °C) Stability • Once Opened: 6 monthsor until manufacturer’s expiration date. WebStatStrip ® Glucose Hospital Connectivity Meter Dimensions: Weight: 0.49 lb (220 g) Size: 5.8 in x 3.1 in x 1.18 in (147 mm x 79 mm x 30 mm) Data Storage: Patient Tests: 1,000 tests QC Tests: 200 tests Users: 4,000 users Connectivity: Meter Data Output: RJ-45 Ethernet Port Protocol: TCP/IP Ethernet 10 Mbit Standard: POCT1-A2 Compliant
WebStatStrip Glucose Test Strips . Tests: Tests Measured: Glucose and Hematocrit Test Reported: Glucose Test Time: 6 Seconds Test Strip Volume: 1.2 µL Test Methodology: … WebStatStrip Controls Linearity Level 1-5 For SCL Healch CV Research Bottle Ea 1387705 Nova Biomedical — 42173 Compare Custom Glucose Level 1 Control For SJRMC Ea 1384081 Nova Biomedical — 41741 Compare StatStrip Custom Glucose Test Strip CLIA Waived Ea 8915594 Nova Biomedical — 42214 Compare
Web11 rows · StatStrip: Manufacturer: Nova Biomedical: Country of Origin: United States: Application: ... WebNova StatStrip Glucose Meter Training Fast Facts Revised 4/2024 . Nova StatStrip Glucose Meter • Reagent Requirements Nova StatStrip Glucose Test Strips Nova StatStrip …
WebA. Nova StatStrip Glucose Meter B. Quality control and cleaning 1. Cleaning the meter a. Clean the meter with a cloth that has been dampened with a 10% bleach ... The operating range or Linearity of the StatStrip Glucose Meter is 10 - 600 mg/dL. 3. Additional Precautions for Neonatal Testing
WebDesigned for applications that do not need data interfacing and connectivity, Xpress2 Glucose retains all of the analytical performance features of StatStrip Glucose. Dimensions: Weight: 2.77 oz (78.5 g) Size: 3.9 in x 2.4 in x 0.9 in (98 mm x 61 mm x 22.9 mm) Data Storage: Patient & QC Tests: 400 tests total (FIFO) Connectivity: northern brewing beerWebNova StatStrip Glucose/Ketone Linearity Kit Lot Number Exp Date UDI# Level 1 L/N 0521025301 Level 2 L/N 0521032302 Level 1 Exp Date 2024-07-25 Level 2 Exp Date 2024-08-01 Spec Mean Result Spec Mean Result Glucose mg/dL 16-22 20 Glucose mg/dL 57-65 62 Ketone mmol/L 0.1-0.2 0.1 northern brickWeb10 rows · StatStrip: Manufacturer: Nova Biomedical: Application : Linearity Kit : Levels : Levels 1 to ... northern briar sea urchin pipeWebDec 5, 2024 · laboratory. The Nova StatStrip meter must be used with Nova StatStrip glucose test strips. 1.4. Glucose is measured with an electrode using an enzyme based test strip … northern briars pipesWebDec 5, 2024 · 6.1. Linearity procedure-performed biannually on each meter. 6.1.1. Remove enough test strips from the bottle and remove the 5 levels of linearity. 6.1.2. Preparation: none; linearity kits come prepared directly from the Nova manufacturer. 6.1.3. Run each level of linearity solution on each meter in duplicate. 6.1.4. Expected results: a. northern bricklayersWebAimStrip + Blood Glucose Testing Kit. Manufacturer: GERMAINE LABORATORIES. G5 Glucose Kits. Manufacturer: DEXCOM. Accu-Chek Linearity Kit. Manufacturer: ROCHE … northern brick companyhttp://novabiomedical.com/statstrip-glu/ northern brick llc